Steam boilers

GOLDENmass Boiler

Solid-fuel-fired steam boilers with stoker-type automatic fuel loading. Design calculations are based on EN-12953 and the Pressure Equipment Directive 2014/68/EU.

Przemysłowy kocioł z szarymi zasobnikami, czerwonymi drzwiczkami i niebieskimi silnikami na białym tle
GOLDENmass Boiler Illustrative photo

Product description

AKUP-type solid-fuel steam boilers

  • AKUP series steam boilers are designed to produce steam using solid fuels.
  • The flue gas flow arrangement is based on the Scotch-type design, while the combustion chamber is specially designed for burning solid fuels delivered by feeders.
  • Fuel is loaded into the combustion chamber automatically by screw fuel feeders.
  • Fuel is conveyed from the hopper to the furnace by a screw feeder system.
  • The number of fuel feeders is selected according to the boiler output.
  • The furnaces are of modular construction, made from high-quality alloy materials with an increased nickel content.
  • The combustion chamber is fitted with special air channels and cooled by air flow.
  • Combustion takes place directly in the specially designed furnace.
  • Thermal calculations are based on nut-size coal with a grain size of 14–25 mm, a calorific value of 6500 kcal/kg and an ash content below 10%.
  • After appropriate modifications, other solid fuels can be burned, such as olive pomace (pirina), wood chips, almond shells and similar biomass fuels.
  • Design calculations are carried out in accordance with the Pressure Equipment Directive 2014/68/EU and EN 12953.
  • High-grade boiler steel and special seamless boiler tubes are used in manufacture.
  • The boiler weight increases in line with the required steam output and design pressure.
  • Depending on the output, the boiler is fitted with one or two fuel feeders.
  • The large steam space ensures high-quality steam.
  • The large water capacity and optimum thermal balance ensure a long service life.
  • The front door is lined with special refractory material resistant to temperatures of up to 1200°C.
  • The exceptionally robust front door design provides easy access for cleaning and complete tightness.
  • The low heat load on the heating surfaces ensures economical, long-term operation with reduced fuel consumption.
  • The boiler body is insulated with high-quality mineral wool and clad with stainless steel or aluminium sheet, effectively reducing heat losses.
  • The optimum design of the flue gas passes ensures high heat transfer efficiency.
  • Thanks to its low fuel consumption, the boiler is an environmentally friendly solution.
  • The boiler body welds are subjected to radiographic testing.
  • On request, the boilers can be supplied as complete package units.

Optional package unit equipment

  • Control panel
  • Control and safety systems: control manifold, electronic water level control system, limit pressure switch, safety probes, safety pressure switch, spring-loaded safety valves
  • Pump set: pumps, strainers, non-return valves, shut-off valves
  • Fuel feed system: fuel hopper, geared motor, combustion air fan, screw feeder
  • Water level gauge
  • Pressure gauge
  • Main steam valve
  • Blowdown and drain valves
  • Drain valve
  • Air vent valve
  • Flue gas extraction fan (induced draught fan)

Technical data

Technical drawing

Rysunek techniczny urządzenia w widoku z przodu i z boku, z wymiarami H, D, L1, L2 oraz F

Technical parameters

Tabela parametrów modeli AKUP 1000–4500: wydajność 1–4,5 t/h oraz wymiary H, D, L1, L2 i F w mm

Need a solution tailored to your requirements?

We will help you select the right system, its parameters and configuration for your specific application. Contact us for more information, an individual quotation and technical details.